Aircel ABP Series Blower Purge
Heated Desiccant Dryer

800 - 10,000 scfm
The ABP Series was created with energy savings and efficient usability in mind. A high efficiency blower brings in ambient air for the regeneration cycle while the Energy Management System and unique Parallel Cooling Mode work seamlessly to create maximum energy savings to the bottom line. Easily link your control system to the 7” Allen-Bradley™ touch screen to monitor and access the controller data through your plant’s overall control system.

• ISO 8573.1 Class 2 (-40°F/-40°C) dew point performance
• 2% average purge consumption
• Making use of the blower to draw in ambient air rather than relying solely on compressed air greatly reduces energy consumption and purge loss
• Fail-safe design: failure of power causes the purge exhaust valves to close, drying air flow is uninterrupted
• Stainless steel desiccant supports and air diffusers to prevent channeling

• Counter-current down flow regeneration, upflow drying, and downflow depressurization
• Ambient air used for heat regeneration, no compressed air used
• 10 minutes of parallel flow with both desiccant chambers online at switch-over to reduce the temperature and moisture spikes

*Scroll to the right on mobile to see entire chart
   Model
Catalog Order
Number
Capacity
Voltage
Connection
Heater kW(full load)
Blower HP
FLA
ABP-800
AG9984030
800
460-3-60
3" FLG
18
5
31.3
ABP-1000
AG9984040
1,000
460-3-60
3" FLG
22
5
36.3
ABP-1200
AG9984050
1,200
460-3-60
3" FLG
27
7.5
46
ABP-1400
AG9984060
1,400
460-3-60
3" FLG
32.5
10
55.9
ABP-1600
AG9984070
1,600
460-3-60
4" FLG
37
10
61.5
ABP-2000
AG9984080
2,000
460-3-60
4" FLG
45
10
71.6
ABP-2500
AG9984090
2,500
460-3-60
4" FLG
52
15
87.4
ABP-3000
AG9984100
3,000
460-3-60
6" FLG
64
15
102.4
ABP-3500
AG9984110
3,500
460-3-60
6" FLG
78
15
120
ABP-4000
AG9984120
4,000
460-3-60
6" FLG
90
15
135.1
ABP-5000
AG9984130
5,000
460-3-60
6" FLG
110
20
166.2
ABP-6000
AG9984140
6,000
460-3-60
8" FLG
120
25
185.7
ABP-7000
AG9984150
7,000
460-3-60
8" FLG
150
25
223.4
ABP-8000
AG9984160
8,000
460-3-60
8" FLG
175
30
260.7
ABP-10000
AG9984180
10,000
460-3-60
8" FLG
200
30
292.1

➤Click Here for ABP Series Capacity Correction Factors

How It Works

• Compressed air flows through the pre-filter to remove oil and then enters the on-line Tower 1 through valve (A).

• Air moves upward, where the desiccant removes moisture from the airstream and lowers the dew point. The majority of clean, dry compressed air exits valve (C) and cycles through the after filter to the rest of the system.

• Tower 2 (shown in regeneration mode) depressurizes to atmosphere through an angle seat valve and muffler (D).

• Valves (E & F) open and the heater turns on.

• The high efficiency blower pulls in ambient air, moving it through the immersion heater and check valve. The ambient airstream passes through valve (F) and flows downward through the moist desiccant in Tower 2, collecting water vapor before exiting valve (E) and exhausting to atmosphere.

• Once Tower 2 exhausts, and the regeneration tower reaches its set point, the heater turns off. This happens regardless of whether the cycle is finished as an energy savings feature of the EMS.

How Aircel ABP Series Works
• A small amount of air exits Tower 1 through a slipstream (B), where it will join Tower 2 to repressurize and cool the tower.

• Ten minutes prior to vessel switchover, the Parallel Cooling Mode will begin (not pictured). Valve (E & H) will close and valves (A & G) will open, allowing incoming air to flow through both towers. This minimizes dew point spikes associated with heated dryers. Parallel Cooling Mode requires no purge air.

• At the end of Parallel Cooling Mode, valve (G) will open, valve (A) will close, and place tower 2 online (not pictured). The EMS Settings will determine if this is at a fixed time interval or Demand Control Cycle based on outlet dew point sensor readings.

• Operations will switch and Tower 1 will be regenerated.


Recommended Installation



Optional Features
• NEMA 4X
• NEMA 7
• Vessel Insulation
• Low Ambient Protection
• Digital flow meter
• Valve inlet position switches
• Valve regeneration outlet position switches
• Condensate drain alarm
• High air inlet temperature alarm
• Inlet temperature
• Vessel bed thermocouple temperature (°F)
• Filter differential pressure alarm




*Scroll to the right on mobile to see entire chart
Model
Weight (lbs)
Height (in)
Width (in)
Depth (in)
ABP-800
3,600
100
87
60
ABP-1000
4,500
100
90
60
ABP-1200
5,400
105
98
61
ABP-1400
6,800
106
105
70
ABP-1600
7,500
107
106
81
ABP-2000
9,000
116
106
81
ABP-2500
10,700
116
128
83
ABP-3000
13,400
127
131
111
ABP-3500
15,600
120
134
105
ABP-4000
17,900
128
147
106
ABP-5000
22,300
138
163
109
ABP-6000
26,800
147
169
118
ABP-7000
31,300
Contact Mdi
Contact Mdi
Contact Mdi
ABP-8000
35,800
Contact Mdi
Contact Mdi
Contact Mdi
ABP-10000
44,700
Contact Mdi
Contact Mdi
Contact Mdi